Your Stamtec press is humming along, working just as it should, when, suddenly, there’s a lube fault warning on the press controls, and production stops.
There’s no need to panic, but there are steps you can take to troubleshoot the issue and get your press back online.
Step 1: Very first thing to do is to check and make sure there’s enough grease in the grease cannister. If there’s not, add grease till it’s up to the proper level, making sure to use the external zerk fitting to do so. Do not try to take the plunger out to refill the cannister – this will only cause excessive air pockets and increase your problems. Cycle the pump and see if the lube fault is cleared, if not move to Step 2.